High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: ETC (Electronic Throttle Control) System Specifications
Specification
[Throttle Position
Sensor (TPS)]
Throttle angle(°)
Output Voltage (V) [Vref=5V]
TPS1
TPS2
0
0.5
4.5
10
0.96
4.05
...
Kia Niro 2017 (DE HEV) Service Manual: Mass Air Flow Sensor (MAFS) Description and operation
Description
MAFS uses a sensing element made of a hot-film to measure the mass of intake
air entering the engine and to send the signal to the ECM.
A large amount of intake air represents acceleration or high load conditions
while a small amount of intake air represents decelerati ...