High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Cooling Fan Repair procedures
Removal and Installation
Cooling Fan Assembly
1.
Disconnect the negative battery terminal.
2.
Remove the air cleaner and air duct A.
(Refer to Intake and Exhaust System - "Air Cleaner")
3.
Separate the engine c ...
Kia Niro 2017 (DE HEV) Service Manual: Engine Oil Repair procedures
Oil And Filter Replacement
•
Prolonged and repeated contact with mineral oil will result in
the removal of natural fats from the skin, leading to dryness, irritation
and dermatitis ...