High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Switch "OFF" the ignition and disconnect the negative (-) terminal of the auxiliary 12V battery. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) in the direction of arrow.
|
4. |
Unfasten the lever (A) in the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Manifold Absolute Pressure Sensor (MAPS) Description and operation
Description
Manifold Absolute Pressure Sensor (MAPS) is a speed-density type sensor installed
on the surge tank. It senses absolute pressure of the surge tank and transfers the
analog signal proportional to the pressure to the ECM. By using this signal, the
ECM calculates the inta ...
Kia Niro (DE HEV) Owners Manual: Map lamp
■ Type A
■ Type B
• (2) :
- The map lamp and room lamp comes on when a door is opened. The lamps go out
after approximately 30 seconds.
- The map lamp and room lamp comes on for approximately 30 seconds when doors are
unlocked with a transmitter or smart key as long as the doors a ...