Kia Niro: High Voltage Battery Cooling System / Cooling Fan Specifications

Specification

Current

Item
Specification
Motor max current (A)
Below. 3.8

Duty

Duty (%)
Fan Speed (rpm)
10
-
20
1,000
30
1,300
40
1,600
50
1,900
60
2,200
70
2,500
80
2,800
90
3,100
95
3,850

Description and operation
Operation 1. Cooling Fan 2. Cooling duct (inlet) 3. Outlet cooling duct (outlet) ...

Cooling Fan Description and operation
Description Consisting of the main connector, the cooling fan relay and the BLDC motor, the cooling fan is controlled by the BMS ECU PWM signal which varies with the high voltage batt ...

Other information:

Kia Niro 2017 (DE HEV) Service Manual: Normal Condition General market
Normal Maintenance Schedule - For Gasoline Engine [Except Europe (Including Russia)] The following maintenance services must be performed to ensure good emission control and performance. Keep receipts for all vehicle emission services to protect your warranty.Where both mileage ...

Kia Niro 2017 (DE HEV) Service Manual: Heated Oxygen Sensor (HO2S) Specifications
Specification HO2S [Bank 1/Sensor 1] (Linear) Item Specification Heater Resistance (Ω) 2.5 - 4.0 [20°C(68°F)] HO2S [Bank 1/Sensor 2] (Binary type) Item Specification ...