Kia Niro: Charging System / Battery Sensor Repair procedures

Removal
1.

Open the trunk.

2.

Remove the luggage side trim [RH].

(Refer to Body - "Luggage Side Trim")

3.

Turn ignition switch OFF and disconnect the battery negative (-) terminal (A).

4.

Disconnect the battery sensor connector (B).

Battery (-) terminal tightening nut :

7.8 - 9.8 N·m (0.8 - 1.0 kgf·m, 5.2 - 8.7 lb·ft)

5.

Remove the battery sensor (A) by loosening the mounting bolt (B).

Battery sensor cable flange mounting bolt(Chassis ground) :

10.8 - 13.7 N·m (1.1 - 1.4 kgf·m, 8.0 - 10.1 lb·ft)

Installation
1.

Install in the reverse order of removal.

  

When battery sensor signal fault occurs, inspect the vehicle parasitic draw in advance after inspecting the sensor because the sensor will behave abnormally when the parasitic draw is more than 100mA. (Refer to vehicle parasitic current inspection)

  

After reconnecting the battery negative cable, AMS function does not operates until the system is stabilized, about 4 hours.

If disconnecting the negative (-) battery cable from the battery during repair work for the vehicle equipped with AMS function, Battery sensor recalibration procedure should be performed after finishing the repair work. (Refer to Battery Sensor Recalibration Procedure)

  

For the vehicle equipped with a battery sensor, be careful not to damage the battery sensor when the battery is replaced or recharged.

1)

When replacing the battery, it should be same one (type, capacity and brand) that is originally installed on your vehicle. If a battery of a different type is replaced, the battery sensor may recognize the battery to be abnormal.

2)

When installing the ground cable on the negative post of battery, tighten the clamp with specified torque. An excessive tightening torque can damage the PCB internal circuit and the battery terminal .

3)

When recharging the battery, ground the negative terminal of the booster battery to the vehicle body.

Battery Sensor Recalibration Procedure

After reconnecting the battery negative cable, AMS function does not operates until the system is stabilized, about 4 hours. If disconnecting the negative (-) battery cable from the battery during repair work for the vehicle equipped with AMS function, Battery sensor recalibration procedure should be performed after finishing the repair work.

1.

Turn the Iginition switch ON and OFF.

2.

Park the vehicle for about 4 hours with the hood and all doors closed.

Battery Sensor Description and operation
Description Vehicles have many control units that use more electricity. These units control their own system based on information from diverse sensors. It is important to have a stabl ...

Cruise Control System
...

Other information:

Kia Niro 2017 (DE HEV) Service Manual: Battery Repair procedures
Inspection Battery Voltage and Status Check the battery voltage and status using the battery tester. Battery Terminal 1. Move back and forth to check that the battery terminals (A) are loose or corroded.If the terminals are corroded, clean them. ...

Kia Niro (DE HEV) Owners Manual: System malfunction
When the AEB is not working properly, the AEB warning light () will illuminate and the warning message will appear for a few seconds. After the message disappears, the master warning light () will illuminate. In this case, we recommend you to have the vehicle inspected by an authori ...