High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro (DE HEV) Owners Manual: Transmitter precautions
The transmitter will not work if any of the following occurs:
The ignition key is in the ignition switch. (for folding key)
Another vehicle’s smart key is being operated close to your vehicle.
You exceed the operating distance limit (about 10 m [30 feet]).
The battery in the transmitter ...
Kia Niro (DE HEV) Owners Manual: Shift lock system
For your safety, the Dual clutch transmission has a shift lock system which prevents
shifting the transaxle from P (Park) into R (Reverse) unless the brake pedal is
depressed.
To shift the transaxle from P (Park) into R (Reverse):
1. Depress and hold the brake pedal.
2. Start the engine or tu ...