High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) in the direction of arrow.
|
4. |
Unfasten the lever (A) in the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Electric Water Pump(EWP) Specifications
Specification
Item
Specification
Type
Water pump
Operation
Motor drive
Voltage
12 V
Rated currency
2.8 A below
...
Kia Niro 2017 (DE HEV) Service Manual: AVN Remote Controller Components and components location
Components
1. Left Remote Control Switch
(Audio + Hands free + Voice)
2. Right Remote Control Switch
(Cruise+Trip Computer)
...