High Voltage Shut-off Procedures |
|
High voltage components: High Voltage Battery Pack Assembly, Power Relay Assembly (PRA), BMS ECU, Hybrid Power Control Unit (HPCU), Hybrid Drive Motor, HSG, Electric A/C Compressor, Low DC/DC Converter (LDC), Power Cable, Electric Compressor etc. |
1. |
Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) terminal. |
2. |
Remove the safety plug cover (A) under the rear seat..
|
3. |
Unfasten the hook (A) to the direction of arrow.
|
4. |
Unfasten the lever (A) to the direction of arrow.
|
5. |
Remove the safety plug (A).
|
6. |
Wait at least 5 minutes or until the capacitor in the high voltage system is fully discharged. |
7. |
Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Kia Niro 2017 (DE HEV) Service Manual: Hybrid Starter Generator(HSG) Specification
Specification
Item
Specification
Type
PMSM
(Interior Permanent Magnet Synchronous Motor)
Max. output
8.0 kW / 2,160 - 12,000 rpm
Max. torque
35.3 N·m / 0 - 2,160 rpm
...
Kia Niro 2017 (DE HEV) Service Manual: Description and operation
Description
AVN system
The AVN system simplifies system manipulation and by unifying the vehicle information
and user information displays, improves information search and operation experience.
The system is basically composed of a keyboard for the operation of combined
function ...