Kia Niro: Air Conditioning System / Ambient Temperature Sensor Repair procedures

Inspection
1.

Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature.

1. Ambient sensor (+)

2. Sensor ground

Specification

Ambient temperature
[°C (°F)]
Resistance between terminals 1 and 2 (k?)
-30 (-22)
480.41
-20 (-4)
271.21
-10 (14)
158.18
0 (32)
95.1
10 (50)
58.8
20 (68)
37.32
30 (86)
23.76
40 (104)
16.13
50 (122)
10.95

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the front bumper.

(Refer to Body - "Front Bumper Cover")

3.

Disconnect the connector (A) and remove the ambient temperature sensor (B).

4.

Install in the reverse order of removal.

Ambient Temperature Sensor Description and operation
Description Located at the front of the condenser, the ambient temperature sensor detects the ambient air temperature. It is a negative type thermistor; resistance will increase at lo ...

Auto Defogging Sensor Description and operation
Description Installed on the windshield glass, the auto defogging sensor detects humidity to blow out wind for defogging to improve visibility and driver comfort. The air conditioner ...

Other information:

Kia Niro 2017 (DE HEV) Service Manual: Electric EGR Control Valve Specifications
Specification [Motor] Item Specification Coil Resistance (Ω) 2.21 - 2.99 [20°C(68°F)] Pin 2 [Position sensor] Item Specification Sensor Po ...

Kia Niro 2017 (DE HEV) Service Manual: Hazard Lamp Switch Repair procedures
Inspection 1. Check for continuity between terminals. If the continuity is not as specified, replace the hazard lamp switch. [Audio Type] Connector Pin Information No. Description No. ...

© 2016-2024 www.kniro.net